NEWSLETTER
Skip to product information
In stock
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Battery replacement without tools
Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Boost Automatic Voltage Regulation (AVR)
Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
Building Wiring Fault Indicator
This LED informs users of potentially dangerous wiring problems in the wall circuit.
Cold-start capable
Provides temporary battery power when the utility power is out.
Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
Lifetime data recovery warranty
Provides peace of mind by providing professional data recovery services in the event data is lost due to the failure of the unit.
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Transformer Block Spacing
Connect bulky transformer block plugs without covering up other outlets.
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
APC BX1500M uninterruptible power supply (UPS) Line-Interactive 1.5 kVA 900 W 10 AC outlet(s)
Part number
BX1500M
$288.54 CAD
1500 VA, 900 W, 120 V, 5 x NEMA 5-15R(Battery Backup), 5 x NEMA 5-15R(selector_surgetitle), 88 - 139 V, 50/60 Hz, 789 J, 1.83 m, Black
Description
Adjustable voltage sensitivityProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Battery replacement without tools
Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Boost Automatic Voltage Regulation (AVR)
Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
Building Wiring Fault Indicator
This LED informs users of potentially dangerous wiring problems in the wall circuit.
Cold-start capable
Provides temporary battery power when the utility power is out.
Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
Lifetime data recovery warranty
Provides peace of mind by providing professional data recovery services in the event data is lost due to the failure of the unit.
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Transformer Block Spacing
Connect bulky transformer block plugs without covering up other outlets.
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Specifications
| Power | |
|---|---|
| Output power capacity | 1.5 kVA |
| Output power | 900 W |
| Input operation voltage (min) | 88 V |
| Input operation voltage (max) | 139 V |
| Output operation voltage (max) | 120 V |
| Surge energy rating | 789 J |
| Maximum current | 12 A |
| Output frequency regulation | 60 Hz |
| Input frequency | 60 Hz |
| Performance | |
| UPS topology | Line-Interactive |
| Audible alarm modes | Alarm when on battery, Low battery alarm, Overload alarm |
| Waveform | Sine |
| Audible alarm(s) | Yes |
| Features | |
| UPS topology | Line-Interactive |
| Output power capacity | 1.5 kVA |
| Audible alarm modes | Alarm when on battery, Low battery alarm, Overload alarm |
| Output power | 900 W |
| Input operation voltage (min) | 88 V |
| Input operation voltage (max) | 139 V |
| Output operation voltage (max) | 120 V |
| Surge energy rating | 789 J |
| Maximum current | 12 A |
| Waveform | Sine |
| Output frequency regulation | 60 Hz |
| Audible alarm(s) | Yes |
| Input frequency | 60 Hz |
| Ports & interfaces | |
| AC outlets quantity | 10 AC outlet(s) |
| AC outlet types | NEMA 5–15R |
| Cabling technology | 10/100/1000Base-T(X) |
| Ethernet LAN (RJ-45) ports | 1 |
| Battery | |
| Battery technology | Sealed Lead Acid (VRLA) |
| Battery recharge time | 16 h |
| Design | |
| Form factor | Tower |
| Product colour | Black |
| Certification | California (CEC) Battery Charger, FCC Part 15 Class B, UL 1778 |
| Display type | LCD |
| Operational conditions | |
| Operating temperature (T-T) | 0 - 40 °C |
| Storage temperature (T-T) | -15 - 40 °C |
| Operating relative humidity (H-H) | 0 - 95% |
| Storage relative humidity (H-H) | 0 - 95% |
| Technical details | |
| Sustainability certificates | ENERGY STAR |
| Compliance certificates | RoHS |
| Certificates | |
| Certification | California (CEC) Battery Charger, FCC Part 15 Class B, UL 1778 |
| Compliance certificates | RoHS |
| Sustainability | |
| Sustainability certificates | ENERGY STAR |
| Weight & dimensions | |
| Width | 3.94" (100 mm) |
| Depth | 15" (382 mm) |
| Height | 9.84" (250 mm) |
| Weight | 24.3 lbs (11 kg) |
| Package width | 8.94" (227 mm) |
| Package depth | 19.3" (491 mm) |
| Package height | 13.7" (348 mm) |
| Package weight | 28 lbs (12.7 kg) |
| Packaging data | |
| Package width | 8.94" (227 mm) |
| Package depth | 19.3" (491 mm) |
| Package height | 13.7" (348 mm) |
| Package weight | 28 lbs (12.7 kg) |