{"product_id":"cyberpower-pdu41116-power-distribution-unit-pdu-16-ac-outlets-0u-black-pdu41116","title":"CyberPower PDU41116 power distribution unit (PDU) 16 AC outlet(s) 0U Black","description":"\u003cstyle\u003etable.generic tr th {background: #eee;}\u003c\/style\u003eSwitched PDU, 0U rackmount, 16 NEMA 5-15R outlets, 100–120 VAC, 15A (derated to 12A), SNMP\/HTTP remote monitoring, Black\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSwitchable Outlets\u003c\/li\u003e\n\u003cli\u003eCyberPower Management Console\u003c\/li\u003e\n\u003cli\u003eRemote and Local Monitoring\u003c\/li\u003e\n\u003cli\u003eAutomatic Event Notifications\u003c\/li\u003e\n\u003cli\u003eUpgradeable Firmware\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDescription\u003c\/h2\u003e\u003cb\u003eProduct Overview\u003c\/b\u003e\u003cbr\u003eThe CyberPower PDU41116, a 16-outlet, 0U rackmount switched power distribution unit (PDU), provides 120V 15A output. It distributes power to 16 NEMA 5-15R receptacles from a single NEMA 5-15P plug with unfiltered electrical pass-through. The switched outlet receptacles can be managed individually or collectively over the network, using the CyberPower Management Console, web browser, and the RJ45 Ethernet port for network connection, or locally by using the LCD controls. Outlets can be turned on, turned off, or recycled on demand or at programmed times to address a number of needs including remote rebooting of locked equipment, load shedding, power sequencing, and locking out unauthorized loads.\u003cbr\u003e\u003cbr\u003e\u003cb\u003ePower Distribution\u003c\/b\u003e\u003cbr\u003eDelivers AC power to servers, equipment, and connected devices via a power distribution unit.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSwitchable Outlets\u003c\/b\u003e\u003cbr\u003eProvides local and remote control for individual and multiple outlets. Local control: turn on\/turn off outlets and disable unused outlets. Remote control: restart outlets and devices, turn on\/turn off, schedule power on\/off sequencing, and disable unused outlets.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eCyberPower Management Console\u003c\/b\u003e\u003cbr\u003eBuilt into Switched PDUs, a CyberPower Management Console is a hardware interface. Users can remotely switch individual PDU outlets or circuits on and off, either immediately or on a schedule, in order to power cycle connected equipment. It monitors the incoming power and power draw from the PDU, sends notifications based on the power status, and logs events.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eRemote and Local Monitoring\u003c\/b\u003e\u003cbr\u003eThe user is able to track PDU vitals both offsite and onsite. It also provides control to turn on\/off individual outlets or circuits.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAutomatic Event Notifications\u003c\/b\u003e\u003cbr\u003eProvide immediate updates about power events via email, SMS text, or SNMP traps.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eUpgradeable Firmware\u003c\/b\u003e\u003cbr\u003eDownloadable improvements (firmware updates) to programs that run the PDU.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eDigital Display\u003c\/b\u003e\u003cbr\u003eProvides easy-to-read information about amperage, voltage, KW, IP address, and other PDU information.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eNetwork-Grade Plugs and Outlets\u003c\/b\u003e\u003cbr\u003eHighly durable construction ensures the efficient distribution of power in demanding IT or industrial environments to servers, equipment, and connected devices.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eLong Input Power Cord\u003c\/b\u003e\u003cbr\u003eReaches distant power sources, allowing the PDU to be placed where it’s needed.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eCord Retention Tray\u003c\/b\u003e\u003cbr\u003eSecures power cords, keeping them organized and accessible. Helps cords stay plugged in.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eConfigurable Mounting Brackets\u003c\/b\u003e\u003cbr\u003eAllow for installation of the PDU in the following configurations: 0U (vertical, under counter, and wall mount), 1U (horizontal, vertical, under counter, and wall mount), and 2U (horizontal and wall mount).\u003cbr\u003e\u003cbr\u003e\u003cb\u003eDurable Metal Housing\u003c\/b\u003e\u003cbr\u003eProtects internal components and resists damage from impact or abrasions within challenging industrial environments. Also extends the life of the product.\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"generic\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eDesign\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePDU types\u003c\/td\u003e\n\u003ctd\u003eSwitched, Monitored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct colour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eUL 62368-1; FCC Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack capacity\u003c\/td\u003e\n\u003ctd\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing material\u003c\/td\u003e\n\u003ctd\u003eMetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePorts \u0026amp; interfaces\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower plug\u003c\/td\u003e\n\u003ctd\u003eNEMA 5-15P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC outlets quantity\u003c\/td\u003e\n\u003ctd\u003e16 AC outlet(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC outlet types\u003c\/td\u003e\n\u003ctd\u003eNEMA 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial ports quantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet LAN (RJ-45) ports\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eFeatures\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED indicators\u003c\/td\u003e\n\u003ctd\u003eTX \/ RX, Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length\u003c\/td\u003e\n\u003ctd\u003e118.1\" (3 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eUL 62368-1; FCC Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eManagement features\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported network protocols\u003c\/td\u003e\n\u003ctd\u003eTCP\/IP, UDP, DHCP, SNMP, HTTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eCurrent, Power, Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eErgonomics\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED indicators\u003c\/td\u003e\n\u003ctd\u003eTX \/ RX, Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length\u003c\/td\u003e\n\u003ctd\u003e118.1\" (3 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal input voltage\u003c\/td\u003e\n\u003ctd\u003e100 - 120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum current\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal output voltage\u003c\/td\u003e\n\u003ctd\u003e100 - 120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input current per phase\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC input frequency\u003c\/td\u003e\n\u003ctd\u003e50 - 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eCertificates\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eUL 62368-1; FCC Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance certificates\u003c\/td\u003e\n\u003ctd\u003eRoHS, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eOperational conditions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e0 - 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-15 - 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e0 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003e0 - 137795.3\" (0 - 3500 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating altitude\u003c\/td\u003e\n\u003ctd\u003e0 - 590511.8\" (0 - 14999 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e32 - 140 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eWeight \u0026amp; dimensions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e11.9 lbs (5.4 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e1.89\" (48 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e2.2\" (56 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e53.1\" (1349 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eTechnical details\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance certificates\u003c\/td\u003e\n\u003ctd\u003eRoHS, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"CyberPower","offers":[{"title":"Default Title","offer_id":67632669557017,"sku":"PDU41116","price":1143.63,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0963\/3428\/3033\/files\/fmupwobYXEuT3HjIpvI1jQ.c-m.jpg?v=1791016294","url":"https:\/\/itvisionnetworks.ca\/products\/cyberpower-pdu41116-power-distribution-unit-pdu-16-ac-outlets-0u-black-pdu41116","provider":"IT Vision Networks Canada","version":"1.0","type":"link"}