{"product_id":"apc-srt3000rmxla-nc-uninterruptible-power-supply-ups-double-conversion-online-3-kva-2700-w-9-ac-outlets-srt3000rmxla-nc","title":"APC SRT3000RMXLA-NC uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA 2700 W 9 AC outlet(s)","description":"\u003cstyle\u003etable.generic tr th {background: #eee;}\u003c\/style\u003e2U, 8xNEMA 5-20R , 1xNEMA L5-30R, 2700W, 3000VA, 120V 50\/60Hz 432x635x85mm, 31.3kg\u003ch2\u003eDescription\u003c\/h2\u003e\u003cb\u003eSRT3000RMXLA-NCFeatures\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003eAPC Smart-UPS SRT 3000VA RM 120V Network Card\u003cbr\u003eHigh density, double-conversion on-line power protection with scalable runtime\u003cbr\u003eIncludes : CD with software , Documentation CD , Installation guide , Network Management Card , Rack Mounting brackets , Rack Mounting support rails , USB cable , Warranty card\u003cbr\u003e- 10\/100 BaseT Connection\u003cbr\u003eConnect the device to a network using a 10 or 100 BaseT connection\u003cbr\u003e- Battery failure notification\u003cbr\u003eProvides early-warning fault analysis on batteries enabling timely preventive maintenance\u003cbr\u003e- ECO Mode\u003cbr\u003eOperating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection\u003cbr\u003e- Green mode\u003cbr\u003ePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.\u003cbr\u003e- LCD graphics display\u003cbr\u003eText and mimic diagrams that display modes of operation, system parameters and alarms.\u003cbr\u003e- Rack\/Tower convertible\u003cbr\u003eProtects the initial investment in the UPS when migrating from tower to rack-mount environment.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eServiceability\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e- Audible alarms\u003cbr\u003eProvides notification of changing utility power and UPS power conditions\u003cbr\u003e- Disconnected battery notification\u003cbr\u003eWarns when a battery is not available to provide backup power.\u003cbr\u003e- Predicitive failure notification\u003cbr\u003eProvides early-warning fault analysis ensuring proactive component replacement.\u003cbr\u003e- Automatic self-test\u003cbr\u003ePeriodic battery self-test ensures early detection of a battery that needs to be replaced.\u003cbr\u003e- User-replaceable batteries\u003cbr\u003eIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)\u003cbr\u003e\u003cbr\u003e\u003cb\u003eProtection\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e- Generator compatible\u003cbr\u003eEnsures clean, uninterrupted power to protected equipment when generator power is used.\u003cbr\u003e- Cold-start capable\u003cbr\u003eProvides temporary battery power when the utility power is out.\u003cbr\u003e- Power conditioning\u003cbr\u003eProtects connected loads from surges, spikes, lightning, and other power disturbances.\u003cbr\u003e- Input power factor correction\u003cbr\u003eMinimizes installation costs by enabling the use of smaller generators and cabling.\u003cbr\u003e- Frequency and voltage regulation\u003cbr\u003eGives higher application availability by correcting poor frequency and voltage conditions without using the battery.\u003cbr\u003e- Resettable circuit breaker\u003cbr\u003eEasy recovery from overloads; no need to replace a fuse.\u003cbr\u003e- Safety-agency approved\u003cbr\u003eEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eManageability\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e- Network manageable\u003cbr\u003eProvides remote power management of the UPS over the network.\u003cbr\u003e- Serial connectivity\u003cbr\u003eProvides management of the UPS via a serial port.\u003cbr\u003e- SmartSlot\u003cbr\u003eCustomize UPS capabilities with management cards.\u003cbr\u003e- LED status indicators\u003cbr\u003eQuickly understand unit and power status with visual indicators.\u003cbr\u003e- InfraStruXure Manager Compatible\u003cbr\u003eEnables centralized management via the APC InfraStruXure Manager.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAdaptability\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e- Plug-and-Play external batteries\u003cbr\u003eEnsures clean, uninterrupted power to the loads when adding extra runtime to the UPS.\u003cbr\u003e- Flash upgradeable firmware\u003cbr\u003eInstall maintenance releases of firmware remotely using FTP.\u003cbr\u003e- Rack\/Tower convertible\u003cbr\u003eProtects the initial investment in the UPS when migrating from tower to rack-mount environment.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAvailability\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e- Temperature-compensated battery charging\u003cbr\u003eProlongs battery life by regulating the charge voltage according to battery temperature.\u003cbr\u003e- Automatic internal bypass\u003cbr\u003eSupplies utility power to the connected loads in the event of a UPS power overload or fault.\u003cbr\u003e- Intelligent battery management\u003cbr\u003eMaximizes battery performance, life, and reliability through intelligent, precision charging.\u003cbr\u003e- Scalable runtime\u003cbr\u003eAllows additional run time to be quickly added as needed.\u003cbr\u003e- Automatic restart of loads after UPS shutdown\u003cbr\u003eAutomatically starts up the connected equipment upon the return of utility power.\u003cbr\u003e- Hot-swappable batteries\u003cbr\u003eEnsures clean, uninterrupted power to protected equipment while batteries are being replaced\u003cbr\u003e\u003cbr\u003eMarketing \u003cb\u003eFeatures\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e- Avoids costly power problems by keeping your IT equipment and data protected and available.\u003cbr\u003eNetwork grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.\u003cbr\u003e- Low operating and maintenance costs with proven reliability and intelligent battery management.\u003cbr\u003eIntelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down.\u003cbr\u003e- Save time with easy and convenient remote accessibility.\u003cbr\u003eNetwork manageable via serial, USB or optional Ethernet. Includes Powerchute® Network Shutdown Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities.\u003cbr\u003e- Peace of mind that comes with full equipment compatibility and reliability of a leader\u003cbr\u003eProvides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"generic\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power capacity\u003c\/td\u003e\n\u003ctd\u003e3 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power\u003c\/td\u003e\n\u003ctd\u003e2700 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput operation voltage (max)\u003c\/td\u003e\n\u003ctd\u003e120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput operation voltage (max)\u003c\/td\u003e\n\u003ctd\u003e120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge energy rating\u003c\/td\u003e\n\u003ctd\u003e340 J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage Total Harmonic Distortion (THD)\u003c\/td\u003e\n\u003ctd\u003e2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest factor\u003c\/td\u003e\n\u003ctd\u003e3:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003e40 - 70 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePorts \u0026amp; interfaces\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length\u003c\/td\u003e\n\u003ctd\u003e96.1\" (2.44 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC outlets quantity\u003c\/td\u003e\n\u003ctd\u003e9 AC outlet(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC outlet types\u003c\/td\u003e\n\u003ctd\u003eNEMA 5–20R, NEMA L5-30R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower plug\u003c\/td\u003e\n\u003ctd\u003eNEMA L5-30P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB port\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial interface\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial interface type\u003c\/td\u003e\n\u003ctd\u003eRJ-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmartSlot\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet LAN (RJ-45) ports\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePerformance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPS topology\u003c\/td\u003e\n\u003ctd\u003eDouble-conversion (Online)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003eSine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-restart\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Voltage Regulation (AVR)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED indicators\u003c\/td\u003e\n\u003ctd\u003eAlarm, Status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible alarm(s)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eFeatures\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPS topology\u003c\/td\u003e\n\u003ctd\u003eDouble-conversion (Online)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power capacity\u003c\/td\u003e\n\u003ctd\u003e3 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeb-based management\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power\u003c\/td\u003e\n\u003ctd\u003e2700 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput operation voltage (max)\u003c\/td\u003e\n\u003ctd\u003e120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput operation voltage (max)\u003c\/td\u003e\n\u003ctd\u003e120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge energy rating\u003c\/td\u003e\n\u003ctd\u003e340 J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003eSine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage Total Harmonic Distortion (THD)\u003c\/td\u003e\n\u003ctd\u003e2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest factor\u003c\/td\u003e\n\u003ctd\u003e3:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-restart\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Voltage Regulation (AVR)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible alarm(s)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003e40 - 70 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eBattery\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life (max)\u003c\/td\u003e\n\u003ctd\u003e5 year(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery capacity\u003c\/td\u003e\n\u003ctd\u003e454 VAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery technology\u003c\/td\u003e\n\u003ctd\u003eSealed Lead Acid (VRLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of batteries supported\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery recharge time\u003c\/td\u003e\n\u003ctd\u003e3 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot-swap battery\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold start\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic battery test\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement battery cartridge\u003c\/td\u003e\n\u003ctd\u003eAPCRBC152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eDesign\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003eRackmount\/Tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack capacity\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct colour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternational Protection (IP) code\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No.107.3-05, FCC Part 15 Class A, OSHPD, UL 1778\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length\u003c\/td\u003e\n\u003ctd\u003e96.1\" (2.44 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED indicators\u003c\/td\u003e\n\u003ctd\u003eAlarm, Status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay type\u003c\/td\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eOperational conditions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e0 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-15 - 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e0 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e0 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003e0 - 118110.2\" (0 - 3000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eTechnical details\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSustainability certificates\u003c\/td\u003e\n\u003ctd\u003eENERGY STAR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance certificates\u003c\/td\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eCertificates\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No.107.3-05, FCC Part 15 Class A, OSHPD, UL 1778\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance certificates\u003c\/td\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eManagement features\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeb-based management\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eSustainability\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSustainability certificates\u003c\/td\u003e\n\u003ctd\u003eENERGY STAR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eWeight \u0026amp; dimensions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e17\" (432 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e25\" (635 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e3.35\" (85 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e69 lbs (31.3 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage width\u003c\/td\u003e\n\u003ctd\u003e23.6\" (599 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage depth\u003c\/td\u003e\n\u003ctd\u003e34.3\" (871 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage height\u003c\/td\u003e\n\u003ctd\u003e9.69\" (246 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage weight\u003c\/td\u003e\n\u003ctd\u003e88 lbs (39.9 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePackaging data\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage width\u003c\/td\u003e\n\u003ctd\u003e23.6\" (599 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage depth\u003c\/td\u003e\n\u003ctd\u003e34.3\" (871 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage height\u003c\/td\u003e\n\u003ctd\u003e9.69\" (246 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage weight\u003c\/td\u003e\n\u003ctd\u003e88 lbs (39.9 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eLogistics data\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProducts per pallet\u003c\/td\u003e\n\u003ctd\u003e6 pc(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"APC","offers":[{"title":"Default Title","offer_id":52077997981977,"sku":"SRT3000RMXLA-NC","price":6003.65,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0963\/3428\/3033\/files\/q3Met3JaOUu2VMVfh6PNUA.c-m.jpg?v=1773690144","url":"https:\/\/itvisionnetworks.ca\/products\/apc-srt3000rmxla-nc-uninterruptible-power-supply-ups-double-conversion-online-3-kva-2700-w-9-ac-outlets-srt3000rmxla-nc","provider":"IT Vision Networks Canada","version":"1.0","type":"link"}